Analysis of Six Key Technologies on How to Ensure the Safety Performance of LED Display Screen

1 What is the reason why the LED screen is completely black?During the application of the control system, we occasionally encounter the phenomenon that the LED screen is completely black. The same phenomenon may be caused by various reasons. Even the process of screen blackening will vary according to different operations or different environments. For example, it may be black at the moment of power on, black during loading, black after sending, etc1. Please ensure that all hardware, including the control system, is powered on correctly. ( 5V, do not connect reversely or wrongly)

Analysis of Six Key Technologies on How to Ensure the Safety Performance of LED Display Screen 1

2. Check and repeatedly confirm whether the serial port cable used to connect the controller is loose or falling off. (if it turns black during loading, it may be caused by this reason, that is, the communication line is interrupted due to looseness during communication, so the screen turns black. Don't think that the line can't be loose if the screen body doesn't move. Please check it. It's very important to solve the problem quickly.)3. Check and confirm whether the LED screen and the hub distribution board connected to the main control card are tightly connected and inserted reversely.2 Why does the LED display screen appear bright lines for a few seconds or the screen image becomes blurred when it is just powered on?

After the screen controller is properly connected with the computer, hub distribution board and screen, it is necessary to provide 5V power supply to the controller to make it work normally (at this time, do not directly connect with 220V voltage). At the moment of power on, a bright line or "flower screen" will appear on the screen for a few seconds. The bright line or "flower screen" is a normal test phenomenon to remind the user that the screen is about to start working normally. Within 2 seconds, the phenomenon is automatically eliminated and the screen enters the normal working state.

3 The reason why the whole screen of the unit board is not bright or dark1. Visually check whether the power connection line, 26p cable between unit boards and the indicator light of power module are normal.2. Use a multimeter to measure whether the unit board has normal voltage, and then measure whether the voltage output of the power module is normal. If not, it is judged that the power module is broken.

3. Measure the low voltage of the power module and adjust the fine adjustment (the fine adjustment at the power module close to the indicator light) to make the voltage reach the standard.4 What are the reasons for the failure to load or communicate?The reasons for communication failure and loading failure are roughly the same, which may be caused by the following reasons. Please compare with the operation according to the listed items:

Analysis of Six Key Technologies on How to Ensure the Safety Performance of LED Display Screen 2

1. Ensure that the control system hardware is properly powered on.2. Check and confirm that the serial port line used to connect the controller is a straight line rather than a cross line.3. Check and confirm that the serial port connecting wire is intact and there is no looseness or falling off at both ends.

4. Select the correct product model, correct transmission mode, correct serial port number and correct serial transmission rate according to the LED display control software and the selected control card, and correctly set the address and serial transmission rate on the hardware of the control system according to the dial switch diagram provided in the software.5. Check whether the jumper cap is loose or falls off; If the jumper cap is not loose, ensure that the jumper cap is oriented correctly.6. If it still fails to load after the above inspection and correction, please use a multimeter to measure whether the serial port of the connected computer or control system hardware is damaged to confirm whether it should be returned to the computer manufacturer or the control system hardware for testing.

hot searches
US Laptop keyboard For Dell Latitude D610 Notebook Keyboards Rplacement Black Original Laptop Keyboard For Lenovo Ideapad S10-2 Notebook Keyboard White Notebook Adapter 19.5V 2.31A 45W DC 4.5*3.0 mm Laptop AC Adapter Power Charger for HP ProBook 400 430 430 Laptop Power Charger Laptop White Keyboard Replacement For MSI Wind U100 Notebook Keyboards Laptop Replacement Keyboard For Asus M50 Notebook Keyboards Black-1653901811199513 60W 19V 3.16A 5.5*3.0mm DC AC Adapter Laptop Power Adapter For Samsung RV515 RV511 R522 R530 RV420 Laptop Charger Laptop Keyboard Replacement For MSI CR640 Notebook Keyboards NEW US Laptop Keyboard For Asus K45D Notebook Keyboards Replacement Black Laptop Keyboard Replacement For Sony Vaio VPC-EC Notebook Keyboards White Original Laptop Keyboard For HP Envy 4 Notebook Keyboards Replacement Black
hot articles
How You Can Make Money on Laptop Screen Protective Film Products
54
Laptop Battery External Charger Connector Cable - How to Use the Best One for Your Needs
53
What Are the Advantages and Disadvantages of Replacement Laptop Keyboard Keys?
52
Why to Choose a Custom Laptop Keyboard for Your Home
51
A Complete Guide to the Different Kinds of Dell Inspiron Keyboard Key
51
5 Top Tips When It Comes to Laptop Screen Supplier
50
What Are the Best Dell Laptop Keyboard for 2021?
50
How to Choose the Perfect Mac Led Keyboard?
50
How to Choose a Home Central Air Conditioner Is Very Important to Master This Little Trick
50
5 Tips to Buy the Right Keyboard Notebook
50
LED display screen related articles
How to Solve the Problem of Frequent Tripping of the Total Leakage Protector of LED Display Screen
How to Solve the Fault of LED Display Screen
How to Use AT89C51 Single Chip Microcomputer to Control the Circuit Design of LED Display Screen
Four Technologies to Solve the Problem of LED Display Screen
Design Requirements of LED Display Screen