As we all know, LED display is a customized product. Unlike ordinary electronic consumer products, it is a simple trading process, but involves the implementation of a complete set of system design scheme. From pre-sales design, including the design of other related industries, to after-sales construction, installation and maintenance, businesses are often required to complete it.Let's share with you the matters needing attention in the field survey before the sales of LED display:1. Preparation before site survey:
Before departure, you need to communicate with the user to understand the user's specific requirements: Type and size of display screen. Installation environment.
Display content and method. Communication mode.2. Site survey contents:
The wall state, installation mode (inlaid, floor mounted, suspended, wall mounted, supported and pillar) and stress conditions of the installation position of the display screen. According to the specific size of the display screen, confirm whether there are obstacles hindering the installation of the display screen at the installation site. In case of inlaid installation, whether the reserved installation slot is appropriate; If there are decorative partitions on the wall, you must ask the user about the wall condition; In case of column screen installation, be sure to understand the geological conditions. (if there is sediment at the bottom of the geological layer for a long time, it will lead to the risk of column and screen sinking or even collapse. Don't look at it like a flower.)
Power supply on site. The capacity of the machine room or AC transformer, whether the cables need to be rearranged, or whether the wire diameter of the arranged cables meets the requirements; If it is single-phase electricity, whether there is grounding wire; If it is three-phase electricity, whether it is three-phase five wire. In case of rewiring, the length of power cord on site shall be measured accurately.
Know the control position of the display screen and whether the communication line is unblocked. The length of communication line required on site, and whether there are other equipment lines that need to be connected to the control end of the display screen, or understand the switching mode of field signal channel; If users don't understand anything, at least they need to understand the application needs of users, especially theater users. If the user has wired, ask whether the length and quantity of wired are appropriate; The length of cat 5 network cable used in normal synchronization system shall be less than 120m, and the length of non Cat 5 network cable shall be lower; If the number is not enough, the corresponding number of network cables must be increased. If it is too long, appropriate optical cables must be used. Multimode optical fibers must be used within 500 meters, and single-mode optical fibers must be used over 500 meters. Whether it is network cable or optical fiber, there must be backup in quantity.
Tools to be carried, such as tape measure or laser ruler. Whether scaffolding is required or provided by users. Whether the computer is provided by the user. External environment of the site. Whether it is necessary to pay attention to moisture protection for those installed indoors, and whether it is necessary to pay attention to the details of waterproof and lightning protection measures for those installed outdoors; Whether the location is close to the sea and chemical plant, and the degree of air salt, alkali and acid. In addition, external screen users need to observe the viewing distance of the audience, the height of the display screen, and the direction of the sun. Take pictures of all situations encountered on the site with cameras as far as possible, and shoot different details from different angles.
Whether the user has special requirements, whether it can be realized in case of special requirements, and the difficulty of the project. If the merchant is responsible for the construction, he must also go to the local area to understand the specific location of the steel market and building materials market.Special considerations for additional outdoor screens:
(1) The display screen is installed outdoors, often exposed to the sun and rain, wind and dust cover, and the working environment is poor. If the electronic equipment is wet or seriously damp, it will cause short circuit or even fire, failure or even fire, resulting in loss.(2) The display screen may be attacked by strong electric and magnetic fields caused by lightning.(3) The ambient temperature varies greatly. When the display screen works, it must generate a certain amount of heat. If the ambient temperature is too high and the heat dissipation is poor, the integrated circuit may not work normally or even be burned, so that the display system cannot work normally.
If the work flow is not arranged in advance, traveling to distant cities for field survey will have a significant impact on the installation of the display screen. At least, it will cause some trouble to users and affect the service level of the company. Not all display screens must be surveyed by the merchant in person. If it is really inconvenient to go to the site, according to the above situation, after selecting the display screen and control system, the user needs to cooperate with the site survey if conditions permit, or the merchant knows the site situation through other ways.